Cart

Added to cart

Go to cart

Your order qualifies for free 2-day shipping and easy returns

Fixed Gas Find IR Camera

FLIR GF77a

Model: FLIR GF77a 25° CH4 (7–8.5 µm) Go to Product Support
product image

The FLIR GF77a is the first uncooled autonomous leak detection camera from FLIR designed specifically to visualize methane gas. This affordable, fixed-camera solution provides upstream and midstream gas processors, producers, or operators the features they need to continuously monitor for potentially dangerous, invisible methane leaks. Small and lightweight, the FLIR GF77a is packed with FLIR-patented features, such as High Sensitivity Mode (HSM), for improved gas visualization. The GF77a can help oil and gas companies maintain valuable capital equipment, avoid product loss, meet emissions reduction metrics, and ensure safer work practices. The GF77a also comes in a GF77f variant that includes environmental housing for harsh environments.

Sales Contact Contact Sales
  • AFFORDABLE FIXED OGI SOLUTION

    Offers industry-leading features for continuous monitoring applications including High Sensitivity Mode, remote motorized focus, and open architecture for third-party integration.

  • VISUALIZE INDUSTRIAL GASES

    Spectrally-filtered to detect methane gases, improving worker safety and leak location identification with fewer in-person inspections.

  • UNMATCHED CONNECTIVITY

    RTSP and GigE compliant, the GF77a offers flexibility to meet many industrial communication needs and connects to a network for continuous leak detection.

thermal-studio-pro-Exseries.pngProfessional Reports that Help Your Customer and Your Business

The right image analysis and reporting software can greatly improve your business by making it easier for you and your customers to understand the problem and feel confident that you fixed it.

The advanced analysis and decision-making support offered in FLIR Thermal Studio Pro includes a rich set of measurement tools, batch processing, the ability to pre-plan inspection routes, and customized report templates.

 
 

maintenance page_repair.jpg

flir care logo.png     flir protect logo.png

Never Worry About Your Camera Performance Again  

Keep your camera going strong with FLIR CARE and FLIR PROTECT. FLIR CARE provides world-class calibration with performance verification and traceable calibration adjustment services that ensure your thermal data is always accurate. FLIR PROTECT extended warranty and service packages provide a full three years of coverage beyond the respective camera’s factory warranty. FLIR PROTECT customers can also receive a bundled calibration service, discounts on additional services, and options for fast-delivered loaner cameras.

Learn More

FLIR_Line_Ironbow.png

ITC_Logo_Primary.pngBecome a Thermal Studio Expert

Learn to edit images, analyze them, and produce custom reports using FLIR Thermal Studio Suite software with online training from the Infrared Training Center. This virtual class covers everything you need to know, including: 

  • How to adjust image parameters and optimize thermal contrast
  • How to create batch functions for image processing
  • How to design a new report template

Thermal Studio Training 

 

Contact Sales

Want more information on this product?

Call 0049 69-950090 0 to speak with a knowledgeable specialist.

Specifications
Digital I/O connector type
M12 Male 12-pin A-coded (shared with ext. power)
Digital Inputs
2x opto-isolated, Vin (low) = 0 - 1.5 V, Vin (high) = 3-25V
Digital Output Purpose
• Programmatically set • Fault (NC)
Digital Outputs
3x opto-isolated, 0–48 VDC, max. 350 mA (derated to 200 mA at 60. Solid-state opto relay, 1x dedicated as Fault output (NC)
Encoding
Video streaming – RTSP Protocol: H.264 / MPEG4 / MJPEG; GVSP: Uncompressed Radiometric streaming – RTSP Protocol: Compressed JPEG-LS, FLIR radiometric; GVSP: Uncompressed, signal linear, temperature linear, FLIR radiometric
WiFi
Wi-Fi standard – IEEE802.11a/b/g/n
Image Frequency
30 Hz
Thermal Resolution [NETD]
<25 mk at 30°C (86°F)
Accuracy
Range 1: -20° to 80°C (-4° to 176°F) ±3°C (±5°F), Range 2: 0° to 250°C (212° to 482°F): 0° to 100°C (32° to 212°F):±3°C, 100° to 250°C (212° to 482°F):±3%, Range 3: 100° to 500°C (212° to 932°F):±3%
Communication & Data Storage
Connection Type
Wi-Fi: Peer to peer (ad hoc) or infrastructure (network)
Connector
Pan and tilt control: M8 A-coded, male; Wi-Fi: Female RP-SMA (Pan/Tilt is an optional feature)
Digital I/O connector type
M12 Male 12-pin A-coded (shared with ext. power)
Digital Inputs
2x opto-isolated, Vin (low) = 0 - 1.5 V, Vin (high) = 3-25V
Digital Output Purpose
• Programmatically set • Fault (NC)
Digital Outputs
3x opto-isolated, 0–48 VDC, max. 350 mA (derated to 200 mA at 60. Solid-state opto relay, 1x dedicated as Fault output (NC)
Encoding
Video streaming – RTSP Protocol: H.264 / MPEG4 / MJPEG; GVSP: Uncompressed Radiometric streaming – RTSP Protocol: Compressed JPEG-LS, FLIR radiometric; GVSP: Uncompressed, signal linear, temperature linear, FLIR radiometric
Ethernet Communication
GigE Vision ver. 1.2, Client API GenICam compliant, TCP/IP socket-based FLIR proprietary
Ethernet Connector Type
M12 8-pin X-coded, Female
Ethernet Image Streaming
Yes
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 3
Ethernet Protocols
IEEE 1588, SNMP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, sftp (server), FTP (client) SMTP, DHCP, MDNS (Bonjour), uPnP
Multicast
RTSP Protocol, GVSP (GigE Vision) Protocol
Serial Communication
Pan and tilt control: RS232 and RS485 exclusively
Unicast
RTSP Protocol, GVSP (GigE Vision) Protocol
WiFi
Wi-Fi standard – IEEE802.11a/b/g/n
Imaging & Optical
Contrast Enhancement
Histogram equalization (IR only) for RTSP and GVSP video streaming, Image Source 0
Detector Pitch
25 µm
Detector Type
Uncooled microbolometer
Field of view (FOV)
25° lens: 25° × 19° 6° lens: 6.4° × 4.9°
FLIR Screen-EST Mode
No
Focal Length
25° lens: 18 mm 6° lens: 74 mm
Focal Plane Array (FPA) - Spectral range
Uncooled microbolometer/7 – 8.5 µm
Focus
One-shot contrast, motorized, manual
Gas Sensitivity [NECL]
CH4 (<100 ppm × m), N2O (<75 ppm × m), C3H8 (<400 ppm × m), SO2 (<30 ppm x m); ΔT = 10°C, distance = 1 m
Image Frequency
30 Hz
IR Resolution
320 × 240 (76,800) pixels
Minimum Focus Distance
0.3 m (0.98 ft) for 25° lens; 5 m (16.4 ft) for 6° lens
Overlay
Image Source 0: RTSP Protocol: with, without; GVSP (GigE Vision) Protocol, with, without,
Spatial resolution (IFOV)
1.4 mrad/pixel
Spectral Range
7 – 8.5 µm
Thermal Resolution [NETD]
<25 mk at 30°C (86°F)
Video Lamp
Built-in LED light
Visual Focus and FOV
Fixed, 67.2° diagonal
Visual Resolution
1280 × 960 pixels
Measurement & Analysis
Accuracy
Range 1: -20° to 80°C (-4° to 176°F) ±3°C (±5°F), Range 2: 0° to 250°C (212° to 482°F): 0° to 100°C (32° to 212°F):±3°C, 100° to 250°C (212° to 482°F):±3%, Range 3: 100° to 500°C (212° to 932°F):±3%
Atmospheric transmission correction
C
Correction Options
Atmospheric, optics transmission, emissivity, reflected apparent temperature, external optics/window
Emissivity Correction
C
Measurement Corrections
Global object parameters
Object Temperature Range
Range 1: -20° to 80°C (-4° to 176°F), Range 2: 0° to 250°C (212° to 482°F), Range 3: 100° to 500°C (212° to 932°F)
Reflected apparent temperature correction
C
General
Pan/Tilt
Optional feature; Control standard – Pelco D
Size [L × W × H]
123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in)
Weight
0.82 kg (1.8 lbs)
Environmental & Certifications
Encapsulation
IP 54 (IEC 60529)‎ IP66 with accessory
Lens Transmission Correction
C
Power
External Voltage
Allowed range 18-56 VDC, 8 W max
General
PoE or external
Power Consumption
6.8 W at 24 V DC typical 7.0 W at 48 V DC typical 7.3 W at 48 V PoE typical
User Interface
Web interface
Yes
Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.

FLIR GF77a - Model: FLIR GF77a 25° CH4 (7–8.5 µm)